Caracteristici
Active principle:
electromechanical
Actuating play in direction of actuation:
5.5
Actuating speed, maximum:
2
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-25
AS-i Current consumption, maximum:
250
AS-i Device protection:
Internal short-circuit proof
AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum:
31.6
AS-i Operating voltage, minimum:
26.5
AS-i Outputs, DO 0:
Solenoid control
AS-i Outputs, DO 1:
No Function
AS-i Outputs, DO 2:
No Function
AS-i Outputs, DO 3:
No Function
AS-i Parameter bits, P0:
Actuator detected
AS-i Parameter bits, P1:
Solenoid interlock locked
AS-i Parameter bits, P2:
Magnet voltage in tolerance range
AS-i Parameter bits, P3:
Error message - locking/unlocking of the solenoid interlock blocked
AS-i Specification:
Safety-Slave
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; EAC; ASi-SaW
Connector position :
Bottom
Control category to EN13849:
3
Degree of pollution to VDE 0100:
3
EAN ( European Article Number):
4030661396507
EAN (European Article Number):
4030661396507
eCl@ss number, Version 9.0:
27-27-26-03
Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Guard locking monitored:
Yes
Included in delivery:
Actuators must be ordered separately.
Integral System Diagnostics, status :
Yes
Mechanical life, minimum:
1000000
Note (applications):
sliding safety guard; removable guard; hinged safety guard
Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF)
Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage):
Protection against polarity reversal
Note (General):
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
Note (LED switching conditions display):
(1) LED yellow: Channel 2 / AS-i SaW Bit 2.3; (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected; (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1
Note (Manual release):
For maintenance, installation, etc. ; For manual release using M5 triangular key, available as accessory
Note (PFH-value):
up to max. 100,000 switching cycles/year
Note (Relative humidity):
non-condensing; non-icing
Number of actuating directions:
3
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
d
Please note::
Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist.
Product type description:
AZM 161 Z ST1-AS R
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Reaction time, maximum:
100
Relative humidity, maximum:
95
Relative humidity, minimum:
30
Resistance to vibrations to EN 60068-2-6:
10 Hz ... 150 Hz, amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Terminal Connector:
Connector plug M12, 4-pole, (A-coding)
Traceparts, external ID:
69-15022006-905757
Traceparts, product ID:
33-22052019-077196
electrical data
switching frequency:
1000
Housing
ambient conditions
protection class:
IP 67 to IEC/EN 60529