Caracteristici
Active principle:
electromechanical
Actuating speed, maximum:
2
Actuator and interlock combined monitored:
Yes
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-25
AS-i Current consumption, maximum:
100
AS-i Device protection:
Internal short-circuit proof
AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum:
31.6
AS-i Operating voltage, minimum:
26.5
AS-i Outputs, DO 0:
Solenoid control
AS-i Outputs, DO 1:
No Function
AS-i Outputs, DO 2:
No Function
AS-i Outputs, DO 3:
No Function
AS-i Parameter bits, P0:
Safety guard and actuator detected
AS-i Parameter bits, P1:
Solenoid interlock locked
AS-i Parameter bits, P2:
Magnet voltage in tolerance range
AS-i Parameter bits, P3:
Error
AS-i Specification:
Safety-Slave
Available until:
2020-12-31T00:00:00
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; EAC; ASi-SaW
Coding level according to ISO 14119:
Low
Control category to EN13849:
4
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
120
EAN ( European Article Number):
4030661364858
EAN (European Article Number):
4030661364858
eCl@ss number, Version 9.0:
27-27-26-03
Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
general information:
Universal coding
Included in delivery:
Actuators must be ordered separately.
Integral System Diagnostics, status :
Yes
Mechanical life, minimum:
1000000
Note (applications):
sliding safety guard; removable guard; hinged safety guard
Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF) ; FID: periphery error
Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage):
Protection against polarity reversal
Note (Delivery capacity):
Phased-out product
Note (General):
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
Note (LED switching conditions display):
(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0; (2) LED red: Internal device error; (3) LED yellow: Device condition
Note (Relative humidity):
non-condensing
Number of actuating directions:
1
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating voltage:
24 VDC -15% / +10% (stabilised PELV)
Reaction time, maximum:
60
Relative humidity, maximum:
95
Relative humidity, minimum:
30
Resistance to vibrations to EN 60068-2-6:
10 Hz ... 150 Hz, amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Standards:
IEC 61508; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Terminal Connector:
Connector plug M12, 4-pole, (A-coding)
Tightening torque of the screw, maximum:
1
Time to readiness, maximum:
4000
Traceparts, external ID:
69-15022006-935635
Traceparts, product ID:
33-31052019-091719
Housing
ambient conditions
protection class:
IP 67 to IEC/EN 60529