Caracteristici
Ambient temperature, maximum:
60
AS-i Current consumption, maximum:
200
AS-i Device protection:
Internal short-circuit proof
AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum:
31.6
AS-i Operating voltage, minimum:
26.5
AS-i Outputs, DO 0:
Solenoid control
AS-i Outputs, DO 1:
No Function
AS-i Outputs, DO 2:
No Function
AS-i Outputs, DO 3:
No Function
AS-i Parameter bits, P0:
Safety guard closed and can be locked
AS-i Parameter bits, P1:
Solenoid interlock locked
AS-i Parameter bits, P2:
Auxiliary voltage in
AS-i Parameter bits, P3:
Internal device error (FID)
AS-i Specification:
Safety-Slave
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; ECOLAB; EAC; FCC; ASi-SaW
Coding level according to ISO 14119:
High
Control category to EN13849:
4
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
200
EAN (European Article Number):
4030661475219
eCl@ss number, Version 9.0:
27-27-26-03
Enclosure material:
Glass-fibre, reinforced thermoplastic
Ensured switch distance "OFF":
20
Ensured switch distance "ON":
1
general information:
Individual coding, multiple teaching
Guard locking monitored:
Yes
Included in delivery:
Actuators must be ordered separately.
Integral System Diagnostics, status :
Yes
Mechanical life, minimum:
1000000
Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF) ; FID: periphery error
Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage):
Protection against polarity reversal
Note (LED switching conditions display):
(1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active; (2) LED yellow: Device condition (Enabling status); (3) LED red: Internal device error
Note (Mechanical lifetime):
When using as door hinge: ≥ 50.000 operations (Türmassen ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Number of actuating directions:
3
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
Product type description:
AZM300Z-I2-ST-AS
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Reaction time, maximum:
120
Recommendation (actuator):
AZ/AZM300-B1
Resistance to vibrations to EN 60068-2-6:
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Storage and transport temperature, maximum:
90
Storage and transport temperature, minimum:
-10
Terminal Connector:
Connector plug M12, 4-pole, (A-coding)
Time to readiness, maximum:
5000
Safety-relevant key characteristics
Housing
ambient conditions
protection class:
IP 66 to IEC/EN 60529; IP 67 to IEC/EN 60529; IP69K to DIN 40050-9