Caracteristici
Ambient temperature, maximum:
45
Ambient temperature, minimum:
-25
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable length (Master/Slave), maximum:
10
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.25 mm²
Climatic stress:
EN 60068-2-78
Common Cause Failure (CCF), minimum:
65
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Current, Utilisation category AC-15:
6
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
6
Degree of pollution to IEC/EN 60664-1:
2
Diagnostic Coverage (DC) Level, Stop 0:
≥ 99
Drop-out delay in case of "emergency stop", maximum:
15
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN (European Article Number):
4030661446554
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption, maximum:
4
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre, reinforced thermoplastic
Indicated operating states:
OUT, green: release; ON, green: supply voltage U<sub>B</sub>; ERR, red: error channel A + B
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
AgSn0. self-cleaning, positive drive
Mechanical life, minimum:
10000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
safe standstill monitoring
Note (Contact resistance):
in new state
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; The sensor-free standstill monitor checks the e.m.f. of the three phase motor.; The SRB range guard door monitor checks the position of the guard door. ; Monitoring the guard door using a solenoid interlock and a safety switch with separate actuator (A and B).; Release takes place by means of the NO contact (E) only when the run-down movement has been terminated.; After release has taken place, the guard door must be opened.; To secure a guard door
Number of auxiliary contacts:
1
Number of safety contacts:
3
Overvoltage category:
III
Performance level, stop 0, up to:
e
Product type description:
AZR31S1-2SEC/230VAC
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start (after detecting standstill), a:
2000
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls, 50 Hz, minimum:
195.5
Rated AC voltage for controls, 60 Hz, minimum:
195.5
Rated control voltage at AC 50 Hz, maximum:
253
Rated control voltage at AC 60 Hz, maximum:
253
Rated impulse withstand voltage:
4
Rated operating voltage:
230 VAC -15% / +10%
Resistance to vibrations to EN 60068-2-6:
10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), Stop 0, applicable for:
3
Short-circuit recognition:
Yes
Standards:
IEC 61508; EN 60947-5-1
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-40
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category AC15:
230
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing
mechanical data