Caracteristici
Ambient temperature, maximum:
55
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
4 mm²
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Control category to EN13849:
3
Current, Utilisation category AC-15:
2
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
2
Degree of pollution to VDE 0110:
2
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN ( European Article Number):
4030661058986
EAN (European Article Number):
4030661058986
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
5
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre, reinforced thermoplastic
Faults:
Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module; Difference in time setting between channel I and channel II; Cross conclusions to the input lines; Interruption of the input connections
Input resistance at GND:
2000
Input signal, HIGH Signal "1":
10 … 30 VDC
Input signal, LOW Signal "0":
0 … 2 VDC
Integral System Diagnostics, status :
Yes
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Fail-safe delay timer
Note (Cable section):
All indications about the cable section are including the conductor ferrules.
Note (Contact resistance):
in new state
Note (Delivery capacity):
Phased-out product
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults):
The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3; Monitoring time for unlocking of solenoid interlocks; The solenoid interlock releases the guard device only when the set time has elapsed. The time begins to run when the power contactors have dropped out.
Number of safety contacts:
3
Number of signalling outputs:
2
Number of undelayed semi-conductor outputs with signaling functi:
2
Overvoltage category:
III
Performance level, up to:
d
Product type description:
AZS 2305
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
100
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated control voltage at DC, maximum:
27.6
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VDC ± 15 %
Reset after disconnection of supply voltage :
Yes
Resistance to vibrations to EN 60068-2-6:
10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Short-circuit recognition:
Yes
Storage and transport temperature, maximum:
70
Storage and transport temperature, minimum:
-25
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Tightening torque of Clips:
0.4
Voltage, Utilisation category AC15:
250
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
mechanical data