• Nu esti logat

    Intra in cont

BNS36-AS-R


BNS 36 AS


Producător: Schmersal Cod produs: 101194954 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Safety sensor
  • Thermoplastic enclosure
  • no mechanical wear
  • 88 mm x 25 mm x 13 mm
  • Integrated AS-Interface
  • Concealed mounting possible
  • Long life
  • Insensitive to transverse misalignment
  • Insensitive to soiling
  • AS-Interface LED and status display
  • 2 m Pre-wired cable, 2-pole

Caracteristici

Active principle:
Magnetic drive

Actuating element:
Magnet

Ambient temperature, maximum:
60

Ambient temperature, minimum:
-25

AS-i Current consumption, maximum:
50

AS-i Device protection:
Internal short-circuit proof

AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Operating voltage AS-i maximum:
31.6

AS-i Operating voltage, minimum:
18.0

AS-i Outputs, DO 0 … DO 3:
No Function

AS-i Parameter bits, P0 ... P3:
No function

AS-i Profile :
S-0.B.F.E

AS-i Specification:
Safety-Slave

AS-i Version :
V 2.1

AS-i, ID-Code:
0xB

AS-i, ID-Code1:
0xF

AS-i, ID-Code2:
0xE

AS-i, IO-Code:
0x0

Basic quantity unit:
Piece

Certificates:
cULus; TÜV; EAC; ASi-SaW

Coding:
Yes

Control category to EN13849:
4

Degree of pollution to VDE 0100:
3

Direction of motion:
Head-on to the active surface

Door hinge:
Right

EAN ( European Article Number):
4030661362250

EAN (European Article Number):
4030661362250

eCl@ss number, Version 9.0:
27-27-24-02

Enclosure material:
Glass-fibre, reinforced thermoplastic

Ensured switch distance "OFF":
17

Ensured switch distance "ON":
7

Gross weight:
95.000

Height of sensor:
25

Included in delivery:
Actuators must be ordered separately.

Installation conditions (mechanical):
quasi-flush

Integral System Diagnostics, status :
Yes

Length of cable:
2

Length of sensor:
13

Material of the Cable mantle:
LSYY

Mission Time:
20

Net weight:
95.000

Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF)

Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note (AS-i Operating voltage):
Protection against polarity reversal

Note (LED switching conditions display):
(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0; (2) LED yellow: Enabling status

Note (PFH-value):
up to max. 500,000 switching cycles/year

Notice (Switch distance Sn):
Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.

Number of cable wires with indication of cable cross-section:
2

Overvoltage category:
III

Overvoltage category to VDE 0100:
3

Performance level, up to:
e

PFH-value:
0.0000000124

PIN 1:
Brown (AS interface +)

PIN 2:
n.c.

PIN 3:
Blue (AS interface −)

PIN 4:
n.c.

Product group:
Initial

Product name:
BNS 36 AS

Product type description:
BNS 36 AS-R

Rated impulse withstand voltage:
0.8

Rated insulation voltage:
32 VDC

Reaction time, maximum:
100

Recommendation (actuator):
BPS 36-2

Repeat accuracy R:
≤ 0.1 x S<sub>ao</sub>

Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), applicable for:
3

Standards:
IEC 61508

Storage and transport temperature, maximum:
70

Storage and transport temperature, minimum:
-25

Terminal Connector:
Connecting cable, 2 pole

Traceparts, external ID:
69-05102007-017914

Traceparts, product ID:
33-22052019-081432

Wire cross-section:
0.23

Housing

Weight:
95

ambient conditions

protection class:
IP 67 to IEC/EN 60529

Acorda o nota:

Parteneri