Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active principle:
inductive
Actuating panels:
Actuation from top
Ambient temperature, maximum:
65
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; EAC
Control category to EN13849:
4
Current, Utilisation category DC12:
0.25
Current, Utilisation category DC13:
0.25
Degree of pollution to VDE 0100:
3
Delivery scope of Mounting material:
2x Mounting accessories Nuts M30
Duration of risk, maximum:
60
EAN ( European Article Number):
4030661405667
EAN (European Article Number):
4030661405667
eCl@ss number, Version 9.0:
27-27-24-03
EMC rating:
IEC 61000-6-2
Enclosure material:
Plastic
Ensured switch distance "OFF":
15
Ensured switch distance "ON":
8
Housing construction form:
Cylinder, thread
Hysteresis (Switch distance), maximum:
2
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
ISO thread of the sensor:
M30
Note:
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
Note (Characteristic curve):
S: switching distance; V: Axial misalignment; Son: Switch-on distance; Soff: Switch-off distance; Sh: Hysteresis area; Sao: Assured switching distance ON; Sar: Ensured switch distance "OFF"
Note (General):
Evaluation requirements: The switch-off pauses of 250 µs – 1500 µs must be tolerated by the evaluation.
The switch-off time of the safety sensor of 250 μs is additionally extended according the cable length and the capacity of the cable used. Typically a switch off time of 500 μs with 100 m of connection cable is reached.
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Number of Series-wiring of sensors:
31
Operating current (diagnostic output):
150
Output current, (fail-safe output), maximum:
0.25
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 4:
Y1 Safety output 1
PIN 5:
SD serial diagnostic output
PIN 7:
Y2 Safety output 2
PIN 8:
IN serial diagnostic input
Product type description:
CSS 11-300-SD-M-ST
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VAC/DC
Rated operating current (safety outputs):
250
Rated operating voltage, maximum:
26.4 VDC
Rated operating voltage, minimum:
20.4 VDC
Reaction time, maximum:
60
Recommendation (actuator):
CST 30S-1
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
3
Voltage drop Ud, maximum:
5
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
ambient conditions
protection class:
IP69 to IEC 60529