Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active area:
Glass-fibre, reinforced thermoplastic
Active principle:
inductive
Actuating panels:
lateral
Actuator switch distance:
Actuator CST 180-1 / CST 180-2: 10 mm; Actuator CST 34-S-1: 14 mm; Actuator CST 34-S-2: 14 mm; Actuator CST 34-S-3: 14 mm; Actuator CST 34-S-1: 12 mm; Actuator CST 34-S-2: 12 mm; Actuator CST 34-S-3: 12 mm; Actuator CST 180-1 / CST 180-2: 8 mm; Actuator CST 34-S-1: 17 mm; Actuator CST 34-S-2: 17 mm; Actuator CST 34-S-3: 17 mm; Actuator CST 180-1 / CST 180-2: 13 mm
Ambient temperature, maximum:
70
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Cable section, maximum:
8 x 0.35 mm²
Certificates:
cULus; TÜV; EAC
Control category to EN13849:
4
Current derating:
Ambient temperature -25°C … +70°C: ≤ 0.1 A; Ambient temperature -25°C … +65°C: ≤ 0.25 A
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
60
EAN ( European Article Number):
4030661314822
EAN (European Article Number):
4030661314822
eCl@ss number, Version 9.0:
27-27-24-03
EMC rating:
IEC 61000-6-2
Enclosure material:
Glass-fibre, reinforced thermoplastic
Ensured switch distance "OFF":
13; 17
Ensured switch distance "ON":
12; 8
Housing construction form:
Block
Hysteresis (Switch distance), maximum:
1.5
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
Note:
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
Note (General):
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.
Note (Repeat accuracy R):
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle)
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Number of Series-wiring of sensors:
31
Output current, (fail-safe output), maximum:
0.25
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 2:
X1 Safety input 1 White
PIN 4:
Y1 Safety output 1 Black
PIN 5:
OUT Diagnostic output OUT Grey
PIN 6:
X2 Safety input 2 violet
PIN 7:
Y2 Safety output 2 red
PIN 8:
IN without function Pink
Product type description:
CSS 14-34-S-D-M-L
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating current (safety outputs):
250
Reaction time, maximum:
30
Recommendation (actuator):
CST 34-S-2; CST 34-S-3; CST 180-1; CST 180-2; CST 34-S-1
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
3
Terminal Connector:
Cable (Y-UL 2517), 8-pole
Traceparts, external ID:
69-23102006-028778
Traceparts, product ID:
33-22052019-077912
Voltage drop Ud, maximum:
5
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
Technical data
Housing
ambient conditions
protection class: