Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active principle:
inductive
Actuating panels:
Actuation from top
Actuator switch distance:
Actuator CST 34-S-3: 12 mm; Actuator CST 30-1: 15 mm; Actuator CST 30-1: 12 mm; Actuator CST 34-S-3: 10 mm; Actuator CST 30-1: 19 mm; Actuator CST 34-S-3: 16 mm
Ambient temperature, maximum:
55
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Control category to EN13849:
4
Current derating:
Ambient temperature -25°C … +70°C: ≤ 0.1 A; Ambient temperature -25°C … +65°C: ≤ 0.2 A
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Delivery scope of Mounting material:
2x Mounting accessories Nuts M30
Duration of risk, maximum:
30
EAN ( European Article Number):
4030661386805
EAN (European Article Number):
4030661386805
eCl@ss number, Version 9.0:
27-27-24-03
EMC rating:
IEC 61000-6-2
Enclosure material:
Nickel plated brass
Ensured switch distance "OFF":
16; 19
Ensured switch distance "ON":
10; 12
Housing construction form:
Cylinder, thread
Hysteresis (Switch distance), maximum:
2
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
ISO thread of the sensor:
M30
Note:
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
Note (Characteristic curve):
S: switching distance; Son: Switch-on distance; Soff: Switch-off distance; Sh: Hysteresis area; Sao: Assured switching distance ON; Sar: Ensured switch distance "OFF"; X: Axial misalignment
Note (General):
Evaluation requirements: The switch-off pauses of 250 µs – 1500 µs must be tolerated by the evaluation.
The switch-off time of the safety sensor of 250 μs is additionally extended according the cable length and the capacity of the cable used. Typically a switch off time of 500 μs with 100 m of connection cable is reached.
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Number of Series-wiring of sensors:
16
Operating Current:
1100; 500
Output current, (fail-safe output), maximum:
0.5
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 2:
X1 safety input 1: Violet
PIN 4:
Y1 Safety output 1 Black
PIN 5:
OUT diagnostic output: Grey
PIN 6:
X2 Safety input 2 White
PIN 7:
Y2 Safety output 2 red
Product type description:
CSS 15-30-2P+D-M-L
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VAC/DC
Rated operating voltage, maximum:
26.4 VDC
Rated operating voltage, minimum:
20.4 VDC
Reaction time, maximum:
30
Recommendation (actuator):
CST 34-S-3; CST 30-1
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
3
Terminal Connector:
Cable
Voltage drop Ud, maximum:
4
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
Housing
ambient conditions
protection class:
IP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529