Caracteristici
Manufacturer declaration
:
ATEX Zone 2 and 22
Ambient temperature, maximum:
50
Basic quantity unit:
Piece
Clamping force in accordance with ISO14119:
1150
Clamping force, maximum:
1500
Classification ZVEI CB24I, Sink:
C1; C2
Classification ZVEI CB24I, Source:
C2
Coding level according to ISO 14119:
Low
Current consumption of the magnet control at 24V:
10
Current consumption of the safety inputs at 24V:
5
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
200
EAN (European Article Number):
4030661483924
Electrical fuse rating, maximum:
2
Enclosure material:
Glass-fibre, reinforced thermoplastic
Ensured switch distance "OFF":
20
Ensured switch distance "ON":
1
Explosion protection category:
3D; 3G
Explosion protection designation:
D II 3GD; EX nA IIB T5 Gc; EX tc IIIB T95°C Dc X
Explosion protection zones:
22; 2
Impact energy, maximum:
7
Included in delivery:
Actuators must be ordered separately.
Integral System Diagnostics, status :
Yes
Material of the fixing screws:
Stainless steel (V4A)
Mechanical life, minimum:
1000000
Note (General):
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.; For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.; As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Note (LED switching conditions display):
Supply voltage UB: LED green; Operating condition: LED green; Error / functional defect: LED red
Note (Mechanical lifetime):
When using as door hinge: ≥ 50.000 operations (Türmassen ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Number of safety contacts:
2
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 1:
A1 Supply voltage UB
PIN 4:
Y1 Safety output 1
PIN 5:
OUT Diagnostic output
PIN 7:
Y2 Safety output 2
PIN 8:
IN Solenoid control
Protection class (Operating resource):
3
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating current (safety outputs):
250
Reaction time of actuator, maximum:
100
Reaction time of input, maximum:
0.5
Reaction time, maximum:
120
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; IEC 62061
Storage and transport temperature, maximum:
90
Storage and transport temperature, minimum:
-10
Switching frequency, approx.:
0.5
Switching thresholds of fail-safe inputs:
−3 V … 5 V (Low); 15 V … 30 V (High)
Switching thresholds of magnet inputs:
-3 V … 5 V (Low); 15 V … 30 V (High)
Terminal Connector:
Connector M12, 8-pole, A-coded
Time to readiness, maximum:
5000
Type of the fixing screws:
2x M6
Versions:
short-circuit proof, p-type
Voltage drop Ud, maximum:
4
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
ambient conditions
protection class:
IP66 to IEC 60529; IP67 to IEC 60529; IP69 to IEC 60529