EX-AZM300B-ST-1P2P-A-CL


EX-AZM 300


Producător: Schmersal Cod produs: 103012541 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Ex-Zone 2 and 22
  • Thermoplastic enclosure
  • Suitable for mounting to profile systems
  • RFID-technology for needs-based protection against tampering
  • 3 different directions of actuation
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Series-wiring
  • Manual release

Caracteristici

Manufacturer declaration

:
ATEX Zone 2 and 22

Active principle:
RFID

Actuator monitored:
Yes

Ambient temperature, maximum:
50

Basic quantity unit:
Piece

Clamping force in accordance with ISO14119:
1150

Clamping force, maximum:
1500

Classification ZVEI CB24I, Sink:
C1; C2

Classification ZVEI CB24I, Source:
C2

Coding level according to ISO 14119:
Low

Control category:
4

Current consumption of the magnet control at 24V:
10

Current consumption of the safety inputs at 24V:
5

Current leakage:
0.5

Current, Utilisation category DC12:
0.05

Current, Utilisation category DC13:
0.05

Degree of pollution to VDE 0100:
3

Duration of risk, maximum:
200

EAN (European Article Number):
4030661483924

Electrical fuse rating, maximum:
2

Enclosure material:
Glass-fibre, reinforced thermoplastic

Ensured switch distance "OFF":
20

Ensured switch distance "ON":
1

Explosion protection category:
3D; 3G

Explosion protection designation:
D II 3GD; EX nA IIB T5 Gc; EX tc IIIB T95°C Dc X

Explosion protection zones:
22; 2

Gross weight:
1062.000

Impact energy, maximum:
7

Included in delivery:
Actuators must be ordered separately.

Integral System Diagnostics, status :
Yes

Latching:
Yes

Latching force:
25; 50

Manual release:
Yes

Material of the fixing screws:
Stainless steel (V4A)

Mechanical life, minimum:
1000000

Mission Time:
20

No-load current:
100

Note (General):
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.; For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.; As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.

Note (LED switching conditions display):
Supply voltage UB: LED green; Operating condition: LED green; Error / functional defect: LED red

Note (Mechanical lifetime):
When using as door hinge: ≥ 50.000 operations (Türmassen ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Number of safety contacts:
2

Operating Current:
50

Overvoltage category:
III

Overvoltage category to VDE 0100:
3

Performance level, up to:
e

PFD value:
0.000045

PFH-value:
0.00000000052

PIN 1:
A1 Supply voltage UB

PIN 2:
X1 Safety input 1

PIN 3:
A2 GND

PIN 4:
Y1 Safety output 1

PIN 5:
OUT Diagnostic output

PIN 6:
X2 Safety input 2

PIN 7:
Y2 Safety output 2

PIN 8:
IN Solenoid control

Power to lock:
Yes

Product group:
Initial

Protection class (Operating resource):
3

Protection rating:
III

Rated impulse withstand voltage:
0.8

Rated insulation voltage:
32 VDC

Rated operating current (safety outputs):
250

Reaction time of actuator, maximum:
100

Reaction time of input, maximum:
0.5

Reaction time, maximum:
120

Required rated short-circuit current to EN 60947-5-1:
100

Resistance to vibrations to EN 60068-2-6:
10 … 150 Hz, amplitude 0.35 mm

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), applicable for:
3

Series-wiring:
Yes

Short circuit detection:
Yes

Short-circuit recognition:
Yes

Standards:
IEC 61508; ISO 13849-1; IEC 62061

Storage and transport temperature, maximum:
90

Storage and transport temperature, minimum:
-10

Switching frequency, approx.:
0.5

Switching thresholds of fail-safe inputs:
−3 V … 5 V (Low); 15 V … 30 V (High)

Switching thresholds of magnet inputs:
-3 V … 5 V (Low); 15 V … 30 V (High)

Terminal Connector:
Connector M12, 8-pole, A-coded

Time to readiness, maximum:
5000

Type of the fixing screws:
2x M6

Versions:
short-circuit proof, p-type

Voltage drop Ud, maximum:
4

Voltage, Utilisation category DC12:
24

Voltage, Utilisation category DC13:
24

Width of sensor:
85

Safety-relevant key characteristics

Safety functions:
Yes

ambient conditions

protection class:
IP66 to IEC 60529; IP67 to IEC 60529; IP69 to IEC 60529