Caracteristici
Manufacturer declaration
:
ATEX Zone 2 and 22
Absicherung des Sicherheitsausganges:
short-circuit proof, p-type
Active area:
Glass-fibre, reinforced thermoplastic
Active principle:
inductive
Ambient temperature, maximum:
40
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Control category to EN13849:
4
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Delivery scope of Mounting material:
2x nuts M18 x 1
Duration of risk, maximum:
30
EAN ( European Article Number):
4030661347158
EAN (European Article Number):
4030661347158
eCl@ss number, Version 9.0:
27-27-24-02
Electrical fuse rating:
short-circuit proof, p-type
Enclosure material:
Glass-fibre, reinforced thermoplastic
Ensured switch distance "OFF":
10
Ensured switch distance "ON":
7
Explosion protection category:
3D; 3G
Explosion protection designation:
D II 3G Ex nA IIC T6 Gc X; D II 3D Ex tc IIIC T70°C Dc X
Explosion protection zones:
22; 2
Explosion protection: regulations:
EN 60079-0; EN 60079-31; EN 60079-15
Housing construction form:
Cylinder, thread
Hysteresis (Switch distance), maximum:
0.7
Impact energy, maximum:
2
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
ISO thread of the sensor:
M18
Material of the nuts:
Glass-fibre, reinforced thermoplastic
Note (Characteristic curve):
S: switching distance; V: Axial misalignment; Son: Switch-on distance; Soff: Switch-off distance; Sh: Hysteresis area; Sao: Assured switching distance ON; Sar: Ensured switch distance "OFF"
Note (General):
Series-wiring of sensors: 16 safety sensors can be switched in series with self-monitoring. In this case, the dual-channel output of a sensor is switched to/inserted into the input of the next sensor. This does not affect the category 4 in accordance with EN ISO 13849-1.; The voltage drop over a long sensor chain should be taken into account when planning cable routing. Operating voltage, cross-section and length of the cable, temperature, number of sensors connected, but also the input load of the control monitor all affect the voltage drop over the sensor chain.
Note (LED switching conditions display):
Multi-coloured LED: Green, Red, Yellow
Number of cable wires with indication of cable cross-section:
7
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Number of Series-wiring of sensors:
16
Operating Current:
1000; 500
Operating voltage, maximum:
26.4
Operating voltage, minimum:
20.4
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 2:
Y2 Safety output 2 red
PIN 4:
Y1 Safety output 1 Black
PIN 5:
X1 Safety input 1 violet
PIN 6:
X2 Safety input 2 White
PIN 7:
Signalling output Grey
Product type description:
EX-CSS 8-180-2P+D-M-L-3G/D
Protection class (Operating resource):
2
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating voltage:
24 VDC
Reaction time, maximum:
30
Recommendation (actuator):
CST 180-1; CST 180-2
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
3
Terminal Connector:
Cable
Terminal connector, Output:
7-pole
Tightening torque of nuts, maximum:
3
Traceparts, external ID:
69-23102006-028473
Traceparts, product ID:
33-22052019-077908
Voltage drop Ud, maximum:
4
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
Housing
ambient conditions
protection class:
IP67; IP65