Caracteristici
Actuating element:
Angle roller lever
Actuating force, minimum:
17
Actuating speed, maximum:
0.5
Ambient temperature, maximum (Cable section 1mm2):
50
Ambient temperature, maximum (Cable section 2.5mm2):
55
Ambient temperature, minimum:
-20
B10d Normally-closed contact (NC):
20000000
Basic quantity unit:
Piece
Bounce duration, maximum:
3
Cable cross-section of the cable glands, maximum:
12
Cable cross-section of the cable glands, minimum:
7
Cable section, maximum:
2.5 mm²
Cable section, minimum:
1 mm²
Certificates:
IECEx; cULus
EAN (European Article Number):
4030661448657
eCl@ss number, Version 9.0:
27-27-26-01
Enclosure coating material:
painted
Enclosure material:
Zinc die-cast
Explosion protection category:
2G; 2D
Explosion protection designation:
D II 2D Ex tb IIIC T80°C Db; D II 2G Ex d e IIC T6 Gb
Explosion protection zones:
1; 21
Explosion protection: regulations:
EN 60079-0; EN 60079-31; EN 60947-5-1; EN 60079-1; EN 60079-7
Housing construction form:
Norm construction design
Impact energy, maximum:
7
Material of the contacts, electrical:
Silver
Max. fuse rating:
6 A gG D-fuse
Mechanical life, minimum:
1000000
Note (Actuating speed):
Actuating speed with actuating angle 30° to switch axis
Note (Cable section):
All indications about the cable section are including the conductor ferrules.
Note (Switchover time):
Switchover time in accordance with actuating speed
Number of auxiliary contacts:
1
Number of safety contacts:
1
Product name:
EX-T 335 angle roller lever 3K
Product type description:
EX-T3K335-11YUE
Rated impulse withstand voltage:
4
Rated insulation voltage:
250 V
Switching element:
NO contact, NC contact
Switching principle:
Slow action with overlapping contacts
Terminal Connector:
Screw connection
Utilisation category:
AC-1
Safety-relevant key characteristics
electrical data
switching frequency:
1800
Housing
ambient conditions