Caracteristici
Manufacturer declaration
:
ATEX Zone 2 and 22
Actuating element:
Rod lever
Actuating speed, maximum:
1
Actuating speed, minimum:
4122
Actuating torque, minimum:
0.15
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-20
B10d Normally open contact (NO):
1000000
Cable cross-section of the cable glands, maximum:
12
Cable cross-section of the cable glands, minimum:
6
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.75 mm²
Enclosure coating material:
painted
Explosion protection category:
3D; 3G
Explosion protection designation:
D II 3D Ex tc IIIC T90°C Dc X; D II 3G Ex nC IIC T5 Gc X
Explosion protection zones:
22; 2
Explosion protection: regulations:
EN 60079-31; EN 60079-15; IEC 60079-0
Housing construction form:
Norm construction design
Length x Width x Height:
Height of sensor: 98.5 mm (without rod)
Lever material:
Metal film
Material of the contacts, electrical:
Silver
Material of the rod:
Plastic
Max. fuse rating:
6 A gG D-fuse
Mechanical life, minimum:
20000000
Note (Actuating speed):
Actuating speed with actuating angle 30° to switch axis
Note (Cable section):
All indications about the cable section are including the conductor ferrules.
Note (General):
Switch with 2 NO contacts are not for security tasks
Note (Switchover time):
Switchover time in accordance with actuating speed
Note Bounce duration:
Bounce duration in accordance with actuating speed
Number of auxiliary contacts:
2
Product name:
EX-T 235 rod lever 10H
Rated impulse withstand voltage:
6
Rated insulation voltage:
500 V
Switching element:
Normally open contact (NO)
Switching principle:
Slow action with staggered contacts
Terminal Connector:
Screw connection
Traceparts, external ID:
69-15022006-919216
Traceparts, product ID:
33-22052019-077397
Utilisation category:
DC-13; AC-15
Utilisation category AC-15:
230
Utilisation category DC-13:
24
electrical data
switching frequency:
5000
ambient conditions