Caracteristici
Active principle:
inductive
Ambient temperature, maximum:
55
Ambient temperature, minimum:
-25
AS-i Current consumption, maximum:
100
AS-i Device protection:
Internal short-circuit proof
AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum:
31.6
AS-i Operating voltage, minimum:
26.5
AS-i Outputs, DO 0:
Solenoid control
AS-i Outputs, DO 1:
For the variable setting of the latching force
AS-i Outputs, DO 2:
For the variable setting of the latching force
AS-i Outputs, DO 3:
For the variable setting of the latching force
AS-i Parameter bits, P0:
Actuator in
AS-i Parameter bits, P1:
Solenoid interlock locked
AS-i Parameter bits, P2:
Auxiliary voltage in
AS-i Parameter bits, P3:
Device error (fault detected)
AS-i Specification:
Safety-Slave
Basic quantity unit:
Piece
Certificates:
cULus; EAC; ASi-SaW
Coding level according to ISO 14119:
Low
Control category to EN13849:
4
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
150
EAN ( European Article Number):
4030661383200
EAN (European Article Number):
4030661383200
eCl@ss number, Version 9.0:
27-27-26-03
Enclosure material:
Glass-fibre, reinforced thermoplastic
general information:
Universal coding
Included in delivery:
Actuators must be ordered separately.
Integral System Diagnostics, status :
Yes
Latching force, maximum:
100
Latching force, minimum:
30
Mechanical life, minimum:
1000000
Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF)
Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage):
Protection against polarity reversal
Note (General):
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.; As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Note (LED switching conditions display):
(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0; (3) LED red: Internal device error; (2) LED yellow: Device condition
Note (Mechanical lifetime):
Operations for door weights ≤ 5 kg; Actuating speed < 0.5 m/s
Note (Relative humidity):
non-condensing; non-icing
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
Product type description:
MZM 100 B ST-AS REMAP
Protection class (Operating resource):
3
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating voltage:
24 VDC -15% / +10% (stabilised PELV)
Reaction time, maximum:
150
Recommendation (actuator):
MZM 100-B1.1
Relative humidity, maximum:
95
Relative humidity, minimum:
30
Resistance to vibrations to EN 60068-2-6:
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Standards:
IEC 61508; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Terminal Connector:
Connector plug M12, 4-pole, (A-coding)
Time to readiness, maximum:
4000
Traceparts, external ID:
69-05102007-016632
Traceparts, product ID:
69-05102007-016632
Safety-relevant key characteristics
Housing
ambient conditions
protection class:
IP 67 to IEC/EN 60529