• Nu esti logat

    Intra in cont

POG 11 + FSL


Encoder incremental


Producător: Baumer Cod produs: 29328 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Offshore and salt water firm, high protection IP 67
  • TTL output driver for cable length up to 550 m
  • Mechanical speed monitoring based on centrifugal force
  • EURO flange B10 / solid shaft ø11 mm
  • Terminal boxes, turn by 180°

Technical data - electrical ratings

Interference immunity:
EN 61000-6-2

Emitted interference:
EN 61000-6-3

Approval:
CE

Technical data - electrical ratings (encoder)

Voltage supply:
9...30 VDC
5 VDC ±5 %

Consumption w/o load:
≤100 mA

Pulses per revolution:
300 … 5000

Phase shift:
90 ° ±20°

Duty cycle:
40…60 %

Reference signal:
Zero pulse, width 90°

Output frequency:
≤120 kHz
≤300 kHz (on request)

Output signals:
K1, K2, K0 + inverted
Error output (option EMS)

Output stages:
HTL-P (power linedriver)
TTL/RS422

Sensing method:
Optical

Technical data - mechanical design

Size (flange):
ø115 mm

Shaft type:
ø11 mm solid shaft

Flange:
EURO flange B10

Protection DIN EN 60529:
IP 67

Speed (n):
≤1,25 · ns

Admitted shaft load:
≤300 N axial
≤450 N radial

Range of switching speed (ns):
850...4500 rpm (Δn = 2 rpm/s)

Material:
Housing: aluminium die-cast
Shaft: stainless steel

Operating torque typ.:
3 Ncm

Corrosion protection:
IEC 60068-2-52 Salt mist
for ambient conditions CX (C5-M) according to ISO 12944-2

Operating temperature:
-40...+100 °C
-25...+100 °C (>3072 pulses)

Rotor moment of inertia:
220 gcm²

Resistance:
IEC 60068-2-6
Vibration 10 g, 10...2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms

Weight approx.:
2,3 kg
2,5 kg (with option M)

Connection:
2x terminal box
3x terminal box (with option M)

Technical data - electrical ratings (centrifugal switch)

Switching accuracy:
± 4 % (Δn = 2 rpm/s);
20 % (Δn = 1500 rpm/s)

Switching deviation:
≤3 % (cw-ccw rotation)

Switching hysteresis:
40 % of switching speed

Switching outputs:
1 output, speed control

Output switching capacity:
≤6 A / 230 VAC
≤1 A / 125 VDC

Minimum switching current:
50 mA