Caracteristici
Ambient temperature, maximum:
55
Ambient temperature, minimum:
-25
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
1.5 mm²
Cable section, minimum:
0.14 mm²
Certificates:
CCC; cULus; EAC
Climatic stress:
EN 60068-2-78
Common Cause Failure (CCF), minimum:
65
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Control category to EN13849:
3
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
2
Degree of pollution to VDE 0110:
2
Diagnostic Coverage (DC) Level:
60
Drop-out delay in case of "emergency stop", maximum:
10
Drop-out delay in case of power failure, maximum:
60
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
1.7
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated
Indicated operating states:
Position relay K3; Position relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>; Position relay K3
Input resistance at GND:
2900
Input resistance at Ue:
2900
Input signal, HIGH Signal "1":
19 - 28,8 VDC
Input signal, LOW Signal "0":
0 - 1 VDC
Integral System Diagnostics, general:
Yes
Mechanical life, minimum:
10000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light curtain
Note (Contact resistance):
in new state
Number of auxiliary contacts:
2; 9
Number of signalling outputs:
7
Overvoltage category:
III
Performance level, up to:
d
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP20
Protection class of the enclosure:
IP20
Pull-in delay at automatic start, maximum, typically:
10
Rated AC voltage for controls at DC minimum:
21.1
Rated AC voltage for controls, 50 Hz, minimum:
21.1
Rated AC voltage for controls, 60 Hz, minimum:
21.1
Rated control voltage at AC 50 Hz, maximum:
26.4
Rated control voltage at AC 60 Hz, maximum:
26.4
Rated control voltage at DC, maximum:
28.8
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VDC -15% / +20%, residual ripple max. 10 %
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Short-circuit recognition:
Yes
Standards:
IEC 61508; EN 60947-5-1
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-40
Switching capacity, maximum:
24
Switching capacity, minimum:
10
Terminal Connector:
Screw connection, plug-in
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing