• Nu esti logat

    Intra in cont

RSS 36-I1-SD-ST


RSS 36


Producător: Schmersal Cod produs: 101218831 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
  • Individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • 1 x connector socket M12, 8-pole
  • Actuation from side
  • Max. 31 sensors can be wired in series.
  • serial diagnostic output

Caracteristici

Absicherung des Diagnoseausganges:
short-circuit proof

Absicherung des Sicherheitsausganges:
short-circuit proof

Active area:
Glass-fibre, reinforced thermoplastic

Active principle:
RFID

Actuating panels:
lateral

Ambient temperature, maximum:
70

Ambient temperature, minimum:
-25

Basic quantity unit:
Piece

CADENAS:
Yes

Cascadable:
Yes

Certificates:
cULus; TÜV; ECOLAB; EAC; FCC; IC

Coding level according to ISO 14119:
High

Control category to EN13849:
4

Current derating:
Ambient temperature -25°C … +70°C: ≤ 0.1 A; Ambient temperature -25°C … +65°C: ≤ 0.25 A

Current leakage:
0.5

Current, Utilisation category DC12:
0.25

Current, Utilisation category DC13:
0.25

Degree of pollution to VDE 0100:
3

Diagnostic output:
Yes

Duration of risk, maximum:
200

EAN (European Article Number):
4030661416359

eCl@ss number, Version 9.0:
27-27-24-03

Electrical fuse rating:
short-circuit proof

EMC rating:
IEC 60947-3

Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Ensured switch distance "OFF":
20

Ensured switch distance "ON":
10

EPLAN:
Yes

general information:
Individual coding

Gross weight:
113.480

Height of sensor:
25

Housing construction form:
Block

Hysteresis (Switch distance), maximum:
2

Included in delivery:
Actuators must be ordered separately.

Installation conditions (mechanical):
not flush

Integral System Diagnostics, status :
Yes

Interfering radiation:
IEC 61000-6-4

Length of sensor:
22

Material temperature resistance (long-term), maximum:
105

Material temperature resistance of the cable (at rest), minimum:
-30

Material temperature resistance of the cable (in motion), minimu:
-10

Mission Time:
20

Mounting:
A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Net weight:
113.480

No-load current:
100

Note:
The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Note (General):
During the individual coding, a RST actuator is taught through a simple routine during start-up, so that any tampering by means of a spare or substitute actuator is permanently excluded.

Note (LED switching conditions display):
LED green: Supply voltage; LED red: Fault; LED yellow: Operating condition

Note (Repeat accuracy R):
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm.

Number of fail-safe digital outputs:
2

Number of LEDs:
3

Number of semi-conductor outputs with signaling function:
1

Number of Series-wiring of sensors:
31

Operating Current:
600

Operating current (diagnostic output):
150

Output current, (fail-safe output), maximum:
0.25

Overvoltage category:
III

Overvoltage category to VDE 0100:
3

Performance level, up to:
e

PFH-value:
0.00000000027

PIN 1:
A1 Ue Brown

PIN 2:
X1 Safety input 1 White

PIN 3:
A2 GND Blue

PIN 4:
Y1 Safety output 1 Black

PIN 5:
serial diagnostic output OUT Grey

PIN 6:
X2 Safety input 2 violet

PIN 7:
Y2 Safety output 2 red

PIN 8:
IN serial diagnostic input Pink

Product group:
Initial

Product name:
RSS 36

Product type description:
RSS 36-I1-SD-ST

Protection class (Operating resource):
3

Protection rating:
III

Rated impulse withstand voltage:
0.8

Rated insulation voltage:
32 VDC

Rated operating current (safety outputs):
250

Rated operating voltage:
24 VDC −15 % / +10 %

Rated operating voltage, maximum:
26.4 VDC

Rated operating voltage, minimum:
20.4 VDC

Reaction time, maximum:
100

Recommendation (actuator):
RST 36-1; RST 36-1-R

Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC

Repeat accuracy R:
0.5

Required rated short-circuit current to EN 60947-5-1:
100

Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), applicable for:
3

Sensor topology:
Sensor for series wiring

Serial diagnostics:
Yes

Short circuit detection:
Yes

Short-circuit recognition:
Yes

Standards:
IEC 61508; ISO 13849-1; EN 62061; IEC 60947-5-3

Storage and transport temperature, maximum:
85

Storage and transport temperature, minimum:
-25

Switch distance:
12

Switching frequency, approx.:
1

Terminal Connector:
Connector M12, 8-pole

Time to readiness, maximum:
2000

Traceparts, external ID:
69-13042011-105125

Traceparts, product ID:
69-13042011-105125

Versions:
p-type

Voltage drop Ud, maximum:
2

Voltage type:
DC (direct current)

Voltage, Utilisation category DC12:
24

Voltage, Utilisation category DC13:
24

Width of sensor:
106.3

Safety-relevant key characteristics

Safety functions:
Yes

ambient conditions

protection class:
IP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529; IP 69 to IEC/EN 60529

Acorda o nota:

Produse asemanatoate


Parteneri