Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active area:
Glass-fibre, reinforced thermoplastic
Actuating panels:
lateral
Ambient temperature, maximum:
70
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; ECOLAB; EAC; FCC; IC
Coding level according to ISO 14119:
High
Control category to EN13849:
4
Current derating:
Ambient temperature -25°C … +70°C: ≤ 0.1 A; Ambient temperature -25°C … +65°C: ≤ 0.25 A
Current, Utilisation category DC12:
0.25
Current, Utilisation category DC13:
0.25
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
200
EAN (European Article Number):
4030661416335
eCl@ss number, Version 9.0:
27-27-24-03
Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Ensured switch distance "OFF":
20
Ensured switch distance "ON":
10
general information:
Individual coding, multiple teaching
Housing construction form:
Block
Hysteresis (Switch distance), maximum:
2
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
Material temperature resistance (long-term), maximum:
105
Material temperature resistance of the cable (at rest), minimum:
-30
Material temperature resistance of the cable (in motion), minimu:
-10
Mounting:
A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
Note:
The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current
Note (General):
Teaching of the individual coding of a RST actuator through a simple routine during start-up (as -I1). A protected coding process enables teaching a new actuator in case of maintenance.
Note (LED switching conditions display):
LED green: Supply voltage; LED red: Fault; LED yellow: Operating condition
Note (Repeat accuracy R):
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).
Minimum clearance between two sensor systems 100 mm.
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Number of Series-wiring of sensors:
31
Operating current (diagnostic output):
150
Output current, (fail-safe output), maximum:
0.25
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 2:
X1 Safety input 1 White
PIN 4:
Y1 Safety output 1 Black
PIN 5:
serial diagnostic output OUT Grey
PIN 6:
X2 Safety input 2 violet
PIN 7:
Y2 Safety output 2 red
PIN 8:
IN serial diagnostic input Pink
Product type description:
RSS 36-I2-SD-ST
Protection class (Operating resource):
3
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating current (safety outputs):
250
Rated operating voltage:
24 VDC −15 % / +10 %
Rated operating voltage, maximum:
26.4 VDC
Rated operating voltage, minimum:
20.4 VDC
Reaction time, maximum:
100
Recommendation (actuator):
RST 36-1; RST 36-1-R
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; EN 62061; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
1
Terminal Connector:
Connector M12, 8-pole
Time to readiness, maximum:
2000
Traceparts, external ID:
69-13042011-105125
Traceparts, product ID:
69-13042011-105125
Voltage drop Ud, maximum:
2
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
ambient conditions
protection class:
IP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529; IP 69 to IEC/EN 60529