Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active area:
Glass-fibre, reinforced thermoplastic
Actuating panels:
front side; rear; from head
Ambient temperature, maximum:
70
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; EAC; FCC; IC
Coding level according to ISO 14119:
Low
Control category to EN13849:
4
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
200
EAN (European Article Number):
4030661456898
eCl@ss number, Version 9.0:
27-27-24-03
Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Ensured switch distance "OFF":
30
Ensured switch distance "ON":
5
general information:
Universal coding
Housing construction form:
Block
Hysteresis (Switch distance), maximum:
2
Included in delivery:
Actuators must be ordered separately.
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
Mounting:
2 x M5, Cylinder head screw
Note:
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
Note (LED switching conditions display):
LED green: Supply voltage; LED red: Fault; LED yellow: Operating condition; Multi-coloured LED: Green, Red
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Operating current (diagnostic output):
50
Output current, (fail-safe output), maximum:
1
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PFH-value:
0.000000000063
Product type description:
RSS16-D-R-CC
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating current (safety outputs):
1000
Rated operating voltage, maximum:
26.4 VDC
Rated operating voltage, minimum:
20.4 VDC
Reaction time, maximum:
100
Recommendation (actuator):
RST16-1-R
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; EN 62061; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching frequency, approx.:
1
Terminal Connector:
Spring pulley connection
Tightening torque of nuts, maximum:
2
Time to readiness, maximum:
2000
Traceparts, external ID:
69-14112014-145352
Traceparts, product ID:
69-14112014-145352
Voltage drop Ud, maximum:
2
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
ambient conditions
protection class:
IP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529