Caracteristici
Absicherung des Diagnoseausganges:
short-circuit proof
Absicherung des Sicherheitsausganges:
short-circuit proof
Active area:
Glass-fibre, thermoplastic
Actuating panels:
lateral; front side
Ambient temperature, maximum:
65
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Certificates:
cULus; TÜV; EAC; FCC; IC
Coding level according to ISO 14119:
High
Control category to EN13849:
4
Current, Utilisation category DC12:
0.05
Current, Utilisation category DC13:
0.05
Degree of pollution to VDE 0100:
3
Duration of risk, maximum:
200
EAN (European Article Number):
4030661436432
eCl@ss number, Version 9.0:
27-27-24-03
Electrical fuse rating:
short-circuit proof
Enclosure material:
Plastic, thermoplastic, self-extinguishing
Ensured switch distance "OFF" Sar, lateral:
15
Ensured switching distance "OFF", front:
18
Ensured switching distance "ON", front:
10
Ensured switching distance "ON", side:
6
general information:
Individual coding, multiple teaching
Housing construction form:
Block
Hysteresis (Switch distance), maximum:
2
Installation conditions (mechanical):
not flush
Integral System Diagnostics, status :
Yes
Interfering radiation:
IEC 61000-6-4
Mounting:
A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.
Note:
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
Note (LED switching conditions display):
LED green: Supply voltage; LED red: Fault; LED yellow: Operating condition
Note (Repeat accuracy R):
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).
Minimum clearance between two sensor systems 100 mm
Number of fail-safe digital outputs:
2
Number of semi-conductor outputs with signaling function:
1
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
PIN 2:
X1 safety input 1: Brown
PIN 4:
Y1 safety output 1: Yellow
PIN 5:
OUT Diagnostic output OUT Grey
PIN 6:
X2 safety input 2: Pink
PIN 7:
Y2 safety output 2: Blue
PIN 8:
IN without function: Red
Product type description:
RSS260-I2-D-ST
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 VDC
Rated operating voltage:
24 VDC -15% / +10%
Rated operating voltage, maximum:
26.4 VDC
Rated operating voltage, minimum:
20.4 VDC
Reaction time, maximum:
100
Recommendation (actuator):
RST16-1; RST-U-2; RST260-1
Recommended safety switchgear:
PROTECT PSC1; SRB-E-301ST; SRB-E-201LC
Required rated short-circuit current to EN 60947-5-1:
100
Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Sensor topology:
Sensor for series wiring
Short circuit detection:
Yes
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1; EN 62061; IEC 60947-5-3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switch distance:
front 12 mm; lateral 9 mm
Switching frequency, approx.:
1
Terminal Connector:
Connector M8
Time to readiness, maximum:
2000
Traceparts, external ID:
69-28052014-109205
Traceparts, product ID:
69-14042014-087184
Voltage drop Ud, maximum:
2
Voltage type:
DC (direct current)
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Safety-relevant key characteristics
ambient conditions
protection class:
IP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529