• Nu esti logat

    Intra in cont

RSS36-AD-ST-AS


RSS 36 AS


Producător: Schmersal Cod produs: 103001535 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • optionally with integrated magnetic latching
  • Universal coding with RFID technology
  • without latching

Caracteristici

Active principle:
RFID

Ambient temperature, maximum:
70

Ambient temperature, minimum:
-25

AS-i Current consumption, maximum:
100

AS-i Device protection:
Internal short-circuit proof

AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Operating voltage AS-i maximum:
31.6

AS-i Operating voltage, minimum:
18

AS-i Outputs, DO 0 … DO 3:
No Function

AS-i Parameter bits, P0:
Number actuator 01-15 (binary)

AS-i Parameter bits, P1:
Number actuator 01-15 (binary)

AS-i Parameter bits, P2:
Number actuator 01-15 (binary)

AS-i Parameter bits, P3:
Number actuator 01-15 (binary)

AS-i Profile :
S-0.B.F.E

AS-i Specification:
Safety-Slave

AS-i Version :
V 3.0

AS-i, ID-Code:
0xB

AS-i, ID-Code1:
0xF

AS-i, ID-Code2:
0xE

AS-i, IO-Code:
0x0

Basic quantity unit:
Piece

Certificates:
cULus; EAC; ASi-SaW

Coding:
Yes

Coding level according to ISO 14119:
Low

Control category to EN13849:
4

Degree of pollution to VDE 0100:
3

Duration of risk, maximum:
200

EAN (European Article Number):
4030661426396

eCl@ss number, Version 9.0:
27-27-24-03

Enclosure material:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Ensured switch distance "OFF":
16

Ensured switch distance "ON":
10

general information:
Universal coding

Height of sensor:
25

Hysteresis (Switch distance), maximum:
2

Included in delivery:
Actuators must be ordered separately.

Integral System Diagnostics, status :
Yes

Length of sensor:
22

Mechanical life, minimum:
1000000

Mission Time:
20

Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF)

Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note (AS-i Operating voltage):
Protection against polarity reversal

Note (LED switching conditions display):
(1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active; (2) yellow LED: device condition (enabling status) / hysteresis signal / device error

Note (Mechanical lifetime):
Operations for door weights ≤ 5 kg; Actuating speed < 0.25 m/s

Number of actuating directions:
3

Overvoltage category:
III

Overvoltage category to VDE 0100:
3

Performance level, up to:
e

PFD value:
0.0000324

PFH-value:
0.000000000513

PIN 1:
AS-Interface +

PIN 2:
n.c. (≤ 30 VDC)

PIN 3:
AS-Interface -

PIN 4:
n.c. (≤ 30 VDC)

Product group:
Initial

Product name:
RSS 36 AS

Product type description:
RSS 36-AD-ST-AS

Protection class (Operating resource):
2

Protection rating:
II

Rated impulse withstand voltage:
0.8

Rated insulation voltage:
32 VDC

Reaction time, maximum:
100

Recommendation (actuator):
RST 36-1-AD01…15

Repeat accuracy R:
0.5

Resistance to vibrations to EN 60068-2-6:
10 … 55 Hz, amplitude 1 mm

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), applicable for:
3

Standards:
IEC 61508

Storage and transport temperature, maximum:
85

Storage and transport temperature, minimum:
-25

Switch distance:
12

Switching frequency, maximum:
1

Terminal Connector:
Connector plug M12, 4-pole, (A-coding)

Time to readiness, maximum:
5000

Width of sensor:
106.3

Safety-relevant key characteristics

Safety functions:
Yes

Housing

Weight:
57

ambient conditions

protection class:
IP 67 to IEC/EN 60529; IP69K to DIN 40050-9; IP 65 to IEC/EN 60529

Acorda o nota: