Caracteristici
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-25
Basic quantity unit:
Piece
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.25 mm²
Climatic stress:
EN 60068-2-78
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Current, Utilisation category AC-15:
6
Current, Utilisation category DC13:
6
Degree of pollution to IEC/EN 60664-1:
2
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN ( European Article Number):
4250116202218
EAN (European Article Number):
4250116202218
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
3.2
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated
Indicated operating states:
Position relay K2; Position relay K1; Position relay K3
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
Ag-Ni, self-cleaning, positive drive
Mechanical life, minimum:
10000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (Contact resistance):
in new state
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; Applications: #Picture#Bilddata/Sonstige/_quitz01.eps#/Picture# safety relay module for double reset; Start configuration: 2 time-dependent reset/on switches 1st and 2nd monitoring time between the 1st and 2nd reset button from 3 … 30 seconds adjustable through DIP switches; The monitoring time is set through DIP switches located below the cover of the enclosure front. (Factory setting: 3 seconds); Actuator configuration: 1-channel control (output impulse approx. 200 ms) of the reset input of a downstream safety relay module; Edge detection: After the device is reset, the trailing edge is evaluated, so that errors, e.g. welded contacts or manipulations cannot lead to dangerous situations.; (H2) = Feedback circuit
Number of safety contacts:
1
Overvoltage category:
III
PFH-Value Stop 0:
0.00000002
Product type description:
SRB100DR
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
100
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated AC voltage for controls, 50 Hz, minimum:
20.4
Rated AC voltage for controls, 60 Hz, minimum:
20.4
Rated control voltage at AC 50 Hz, maximum:
26.4
Rated control voltage at AC 60 Hz, maximum:
26.4
Rated control voltage at DC, maximum:
28.8
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -15% / +20%, residual ripple max. 10 %
Reset after disconnection of supply voltage :
Yes
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Standards:
IEC 61508; EN 60947-5-1
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-40
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category AC15:
230
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing