Caracteristici
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-25
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.25 mm²
Certificates:
CCC; cULus; EAC; TILVA
Climatic stress:
EN 60068-2-78
Common Cause Failure (CCF), minimum:
65
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Current, Utilisation category DC12:
0.1
Current, Utilisation category, AC15:
3
Current, Utilisation category, DC13:
2
Degree of pollution to VDE 0110:
2
Diagnostic Coverage (DC) Level, Stop 0:
≥ 99
Diagnostic Coverage (DC) Level, Stop 1:
> 60
Drop-out delay in case of emergency, typically:
30
Drop-out delay in case of power failure, typically:
80
EAN (European Article Number):
4030661448923
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
2.4
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated
Indicated operating states:
Position relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>; Position relay K3/K4
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
AgSn0, Ag-Ni, self-cleaning, positive drive
Mechanical life, minimum:
10000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light curtain
Note (Contact resistance):
in new state
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge.; Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2).; The control recognises cross-short, cable break and earth leakages in the monitoring circuit.; For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 ; Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential.; The safety enabling circuit 37/38 conforms to EN 60204-1 for STOP Category 1. The safety enabling circuits 13/14 and 23/24 conform to EN 60204-1 for STOP Category 0.; F1 = Hybrid fuse
Number of safety contacts:
3
Number of Safety contacts, STOP 0:
3
Number of Safety contacts, STOP 1:
2
Number of signalling outputs:
1
Overvoltage category:
III
Performance level, stop 0, up to:
e
Performance level, stop 1, up to:
d
PFH-Value Stop 0:
0.00000002
PFH-Value Stop 1:
0.0000002
Product type description:
SRB 211ST V.2
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
250
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated AC voltage for controls, 50 Hz, minimum:
20.4
Rated AC voltage for controls, 60 Hz, minimum:
20.4
Rated control voltage at AC 50 Hz, maximum:
26.4
Rated control voltage at AC 60 Hz, maximum:
26.4
Rated control voltage at DC, maximum:
28.8
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -15% / +20%, residual ripple max. 10 %
Reset edge detection:
Yes
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), Stop 0, applicable for:
3
Safety Integrity Level (SIL), Stop 1, applicable for:
2
Short-circuit recognition:
Yes
Standards:
IEC 61508; EN 60947-5-1
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-40
Switching capacity, maximum:
24
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category, AC15:
230
Voltage, Utilisation category, DC13:
24
Wire breakage detection :
Yes
Housing
mechanical data