Performance characteristics
Process temperature:
115 … 135 °C , < 1 h
-40 … 115 °C , permanent
Output range:
-50 … 150 °C , programmable
Pt100 accuracy class (EN 60751):
B (± 0.3 °C at 0 °C)
± (0.3 + 0.005 × t)°C
A (± 0.15 °C at 0 °C)
± (0.15 + 0.002 × t)°C
1/3 B (± 0.1 °C at 0 °C)
± 1/3 × (0.3 + 0.005 × t)°C
1/6 B (± 0.05 °C at 0 °C)
± 1/6 × (0.3 + 0.005 × t)°C
Response time, T50:
≤ 2.5 s , 20 mm.
≤ 2.7 s , 50 mm
≤ 9.0 s , front-flush
Max. conversion error:
± 0.25 °C
Max. output error:
± 0.1 % FSR
± 0.016 mA
Temperature drift (by ambient):
< 0.003 % FSR/°C , typ.
< 0.01 % FSR/°C , max.
Response time, T90:
≤ 6.5 s , 20 mm
≤ 6.7 s , 50 mm
≤ 66.0 s , front-flush
Process connection
Immersion length:
0 mm , front-flush
20 mm
50 mm
Wetted parts material:
PEEK Natura
Sensor tube material:
AISI 316L (1.4404)
Surface roughness wetted parts:
Ra ≤ 0.8 µm
Output signal
Without transmitter:
1 x Pt100, 4-wire
With transmitter:
4 … 20 mA , 2-wire
Shunt resistance:
Rs ≤ (Vs - 8 V)/0.023 A
Rs ≤ 680 Ohm, Vs = 24 V DC
ambient conditions
Degree of protection (EN 60529):
IP 67
IP 69K , with appropriate cable
Vibration (sinusoidal) (EN 60068-2-6):
1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Humidity:
< 98 % RH , condensing
Compliance and approvals
EMC:
EN 61000-6-2
EN 61000-6-3
EN 61326-1
Hygiene:
(EU) No 10/2011
(EC) No 1935/2004
(EC) No 2023/2006
3-A (74-07)
FDA (21 CFR 177.2415)