Press reset button and hold. Enter desired value in any order. Release reset button.
Trigger / end contact:
At 0000: As momentary contact: Contact duration dependent on speed e.g. 100 ms, at 10000 rpm and 50 revolutions = 1 digit At 9999: As permanent contact, contact remains until reset. If no reset takes place, the contact switches back at 8999.
Trigger / precontact:
Preset number as momentary contact. End contact as permanent contact
Switching voltage:
230 VAC / VDC
Output contact:
Change-over contact
Switching current:
2 A
Switching capacity:
100 VA / 30 W
Spark extinguisher:
Recommended for inductive load
Preset:
1 preset
Technical data - mechanical design
Function:
Revolution counter with preset
Dimensions W x H x L:
60 x 62 x 68.5 mm
Display:
White numbers on black
Number of digits:
4-digits
Digit height:
5,5 mm
Operating speed:
≤10000 rpm
Housing type:
Surface mount housing
Mounting type:
Surface mount housing
Ambient temperature:
0...+60 °C
Count mode:
Subtracting in a rotational direction to be indicated, adding in reverse direction