Caracteristici
Actuating force, maximum:
200
Ambient temperature, maximum:
60
Ambient temperature, minimum:
-25
AS-i Device protection:
Internal short-circuit proof
AS-i Input, Channel 1:
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2:
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum:
31.6
AS-i Operating voltage, minimum:
18
AS-i Outputs, DO 0 … DO 3:
No Function
AS-i Parameter bits, P0:
Channel 2 switched
AS-i Parameter bits, P1:
No function
AS-i Parameter bits, P2:
No function
AS-i Parameter bits, P3:
No function
Available until:
2020-12-31T00:00:00
Basic quantity unit:
Piece
Certificates:
cULus; EAC; ASi-SaW
Control category to EN13849:
4
Degree of pollution to VDE 0100:
3
EAN (European Article Number):
4030661427362
Enclosure coating material:
painted
Enclosure material:
Zinc die-cast, paint finish
Height of the Sensor, maximum:
236.3
Height of the Sensor, minimum:
220.3
Length of the wire, maximum:
50
Material of the cover:
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Mechanical life, minimum:
100000
Note (AS-i Parameter bits):
Set the parameter outputs to "1111" (0xF) ; FID: periphery error
Note (AS-i Input module address):
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage):
Protection against polarity reversal
Note (Delivery capacity):
Phased-out product
Note (General):
Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature.; As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner.; The addressing must take place via the M12 connector or the flat cable connection.; At 5 m distance intermediate wire supports are required, see accessories
Note (PFH-value):
up to max. 5,000 switching cycles/year
Note (Relative humidity):
non-condensing; non-icing
Overvoltage category:
III
Overvoltage category to VDE 0100:
3
Performance level, up to:
e
Product type description:
ZQ 900 FK-AS
Rated impulse withstand voltage:
0.8
Rated insulation voltage:
32 V
Reaction time, maximum:
100
Relative humidity, maximum:
95
Relative humidity, minimum:
30
Resistance to vibrations to EN 60068-2-6:
10 … 150 Hz, amplitude 0.35 mm; 10 … 150 Hz, with 5 g
Restistance to shock:
15 g / 11 ms
Safety Integrity Level (SIL), applicable for:
3
Storage and transport temperature, maximum:
85
Storage and transport temperature, minimum:
-25
Switching principle:
Snap switch element
Terminal Connector:
Connection for flat cable
electrical data
switching frequency:
3600
ambient conditions
protection class:
IP65; IP67 to IEC 60529