Caracteristici
Ambient temperature, maximum:
55
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.25 mm²
Climatic stress:
EN 60068-2-3; BG-GS-ET-14
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Control category to EN13849:
3
Current, Utilisation category AC-15:
6
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
6
Degree of pollution to IEC/EN 60664-1:
2
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN ( European Article Number):
4030661296920
EAN (European Article Number):
4030661296920
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
5
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated
Faults:
Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module
Input resistance at GND:
4000
Input signal, HIGH Signal "1":
10 … 30 VDC
Input signal, LOW Signal "0":
0 … 2 VDC
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
Ag-Ni 10 and 0.2 µm gold-plated
Mechanical life, minimum:
20000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Safety sensor; Guard system
Note (Contact resistance):
in new state
Note (Delivery capacity):
Phased-out product
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults):
The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; To secure a guard door up to PL d and Category 3; Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range; If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.; Modification for 2 NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X1. In this configuration, the short-circuit detection becomes inoperative.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1.0 s by changing the position of a jumper link connection under the cover of the unit.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.
Number of safety contacts:
1
Number of signalling outputs:
2
Number of undelayed semi-conductor outputs with signaling functi:
2
Overvoltage category:
III
Performance level, up to:
d
Product type description:
AES 1135
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
100
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated AC voltage for controls, 50 Hz, minimum:
20.4
Rated AC voltage for controls, 60 Hz, minimum:
20.4
Rated control voltage at AC 50 Hz, maximum:
26.4
Rated control voltage at AC 60 Hz, maximum:
26.4
Rated control voltage at DC, maximum:
28.8
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10%
Reset after disconnection of supply voltage :
Yes
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1
Storage and transport temperature, maximum:
70
Storage and transport temperature, minimum:
-25
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category AC15:
230
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing
mechanical data