• Nu esti logat

    Intra in cont

SRB301LC/B-24V


Stop category 0


Producător: Schmersal Cod produs: 101177962 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • 3 safety contacts, STOP 0
  • 1 Signalling output

Caracteristici

Ambient temperature, maximum:
45

Ambient temperature, minimum:
-25

Automatic reset function:
Yes

Basic quantity unit:
Piece

Cable section, maximum:
2.5 mm²

Cable section, minimum:
0.25 mm²

Category, Stop 0:
4

Certificates:
CCC; cULus; EAC

Climatic stress:
EN 60068-2-78

Common Cause Failure (CCF), minimum:
65

Conduction resistance, maximum:
40

Contact resistance, maximum:
0.1

Current, Utilisation category AC-15:
6

Current, Utilisation category DC12:
0.1

Current, Utilisation category DC13:
6

Degree of pollution to IEC/EN 60664-1:
2

Diagnostic Coverage (DC) Level, Stop 0:
≥ 99

Drop-out delay in case of emergency, typically:
20

Drop-out delay in case of power failure, typically:
80

EAN ( European Article Number):
4030661315836

EAN (European Article Number):
4250116201686

Earth connection detection:
Yes

eCl@ss number, Version 9.0:
27-37-18-19

Electrical power consumption:
1.7

EMC rating:
EMC-Directive

Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated

Feedback circuit :
Yes

Frequency range:
50; 60

Gross weight:
230.000

Height:
100

Indicated operating states:
Position relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>

Integral System Diagnostics, status :
Yes

Material of the contacts, electrical:
AgSn0. self-cleaning, positive drive

Mechanical life, minimum:
10000000

Mission Time:
20

Mounting:
Snaps onto standard DIN rail to EN 60715

Net weight:
230.000

Note (applications):
Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light curtain

Note (Contact resistance):
in new state

Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; The control system recognises wire-breakage and earth faults in the monitoring circuit.; Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.; Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge.; For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 ; Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential.; Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R); cross-wire monitoring and feedback circuit (H2)

Number of auxiliary contacts:
1

Number of LEDs:
4

Number of openers:
2

Number of safety contacts:
3

Overvoltage category:
III

Performance level, stop 0, up to:
e

PFH-Value Stop 0:
0.00000002

Product group:
Initial

Product name:
SRB 301LC/B

Product type description:
SRB 301LC/B-24V

Protection class of Clips or Terminals:
IP20

Protection class of the Clearance:
IP54

Protection class of the enclosure:
IP40

Pull-in delay at automatic start, maximum, typically:
100

Pull-in delay at RESET, typically:
20

Rated AC voltage for controls at DC minimum:
20.4

Rated AC voltage for controls, 50 Hz, minimum:
20.4

Rated AC voltage for controls, 60 Hz, minimum:
20.4

Rated control voltage at AC 50 Hz, maximum:
26.4

Rated control voltage at AC 60 Hz, maximum:
26.4

Rated control voltage at DC, maximum:
28.8

Rated impulse withstand voltage:
4

Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -15%/+20%, residual ripple max. 10%

Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), Stop 0, applicable for:
3

Standards:
IEC 61508; EN 60947-5-1

Start input:
Yes

Storage and transport temperature, maximum:
85

Storage and transport temperature, minimum:
-40

Switching capacity, maximum:
250

Switching capacity, minimum:
10

Terminal Connector:
Screw connection; rigid or flexible

Terminal designations:
IEC/EN 60947-1

Tightening torque of Clips:
0.6

Voltage, Utilisation category AC15:
230

Voltage, Utilisation category DC12:
24

Voltage, Utilisation category DC13:
24

Width:
22.5

Wire breakage detection :
Yes

Housing

Weight:
230

mechanical data

depth:
121

Acorda o nota:

Produse asemanatoate


Parteneri