Caracteristici
Ambient temperature, maximum:
55
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
2.5 mm²
Climatic stress:
BG-GS-ET-14; IEC 60947-5-3
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Control category to EN13849:
3
Current, Utilisation category AC-15:
6
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
6
Degree of pollution to IEC/EN 60664-1:
2
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN ( European Article Number):
4030661279442
EAN (European Article Number):
4030661279442
Earth connection detection:
Yes
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
5
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre, reinforced thermoplastic
Faults:
Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module
Input resistance at GND:
5000
Input signal, HIGH Signal "1":
12 … 30 VDC
Input signal, LOW Signal "0":
0 … 2 VDC
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
Ag-Ni, Au
Mechanical life, minimum:
50000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Safety sensor; Guard system
Note (Contact resistance):
in new state
Note (Delivery capacity):
Phased-out product
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults):
The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit.; To secure 3 guard doors up to PL d and Category 3; Monitoring 3 guard door(s), each with a magnetic safety sensor of the BNS range; The feedback circuit monitors the position of the contactors K3 and K4.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and S13.; If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.
Notice:
for max. 50,000 switching cycles/year and max. 80% contact load
Number of inputs for NC:
3
Number of inputs for NO:
3
Number of safety contacts:
1
Overvoltage category:
III
Performance level, up to:
d
Product type description:
AES 1185.3
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
100
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated AC voltage for controls, 50 Hz, minimum:
20.4
Rated AC voltage for controls, 60 Hz, minimum:
20.4
Rated control voltage at AC 50 Hz, maximum:
26.4
Rated control voltage at AC 60 Hz, maximum:
26.4
Rated control voltage at DC, maximum:
28.8
Rated impulse withstand voltage:
4
Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10%
Reset after disconnection of supply voltage :
Yes
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1
Storage and transport temperature, maximum:
70
Storage and transport temperature, minimum:
-25
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category AC15:
230
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing
mechanical data