• Nu esti logat

    Intra in cont

AES1265 (24VAC/DC)


Stop category 0


Producător: Schmersal Cod produs: 101170051 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • Monitoring of BNS range magnetic safety sensors
  • 2 safety contacts, STOP 0

Caracteristici

Ambient temperature, maximum:
55

Automatic reset function:
Yes

Basic quantity unit:
Piece

Cable section, maximum:
2.5 mm²

Cable section, minimum:
0.25 mm²

Certificates:
cULus; EAC

Climatic stress:
EN 60068-2-3; BG-GS-ET-14

Conduction resistance, maximum:
40

Contact resistance, maximum:
0.1

Control category to EN13849:
3

Current, Utilisation category AC-15:
6

Current, Utilisation category DC12:
0.1

Current, Utilisation category DC13:
6

Degree of pollution to IEC/EN 60664-1:
2

Drop-out delay in case of emergency, typically:
20

Drop-out delay in case of power failure, typically:
80

EAN ( European Article Number):
4030661297132

EAN (European Article Number):
4030661297132

Earth connection detection:
Yes

eCl@ss number, Version 9.0:
27-37-18-19

Electrical power consumption:
5

EMC rating:
EMC-Directive

Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated

Faults:
Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module

Feedback circuit :
Yes

Frequency range:
50; 60

Gross weight:
174.000

Height:
100

Input resistance at GND:
4000

Input signal, HIGH Signal "1":
10 … 30 VDC

Input signal, LOW Signal "0":
0 … 2 VDC

Integral System Diagnostics, status :
Yes

Material of the contacts, electrical:
Ag-Ni 10 and 0.2 µm gold-plated

Mechanical life, minimum:
20000000

Mission Time:
20

Mounting:
Snaps onto standard DIN rail to EN 60715

Net weight:
174.000

Note (applications):
Safety sensor; Guard system

Note (Contact resistance):
in new state

Note (Delivery capacity):
Phased-out product

Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Note (ISD -Faults):
The following faults are registered by the safety monitoring modules and indicated by ISD.

Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit.; To secure 2 guard doors up to PL d and Category 3; The feedback circuit monitors the position of the contactors K3 and K4.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.; If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and A1.

Notice:
for max. 50,000 switching cycles/year and max. 80% contact load

Number of LEDs:
1

Number of openers:
2

Number of safety contacts:
2

Number of shutters:
2

Number of signalling outputs:
2

Number of undelayed semi-conductor outputs with signaling functi:
2

Overvoltage category:
III

Performance level, up to:
d

PFH-value:
0.0000001

Product group:
Initial

Product name:
AES 126x

Product type description:
AES 1265

Protection class of Clips or Terminals:
IP20

Protection class of the Clearance:
IP54

Protection class of the enclosure:
IP40

Pull-in delay at automatic start, maximum, typically:
100

Pull-in delay at RESET, typically:
20

Rated AC voltage for controls at DC minimum:
20.4

Rated AC voltage for controls, 50 Hz, minimum:
20.4

Rated AC voltage for controls, 60 Hz, minimum:
20.4

Rated control voltage at AC 50 Hz, maximum:
26.4

Rated control voltage at AC 60 Hz, maximum:
26.4

Rated control voltage at DC, maximum:
28.8

Rated impulse withstand voltage:
4

Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10%

Reset after disconnection of supply voltage :
Yes

Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), applicable for:
2

Short-circuit recognition:
Yes

Standards:
IEC 61508; ISO 13849-1

Storage and transport temperature, maximum:
70

Storage and transport temperature, minimum:
-25

Switching capacity, maximum:
250

Switching capacity, minimum:
10

Terminal Connector:
Screw connection; rigid or flexible

Terminal designations:
IEC/EN 60947-1

Thermal test current:
6

Tightening torque of Clips:
0.6

Voltage, Utilisation category AC15:
230

Voltage, Utilisation category DC12:
24

Voltage, Utilisation category DC13:
24

Width:
22.5

Wire breakage detection :
Yes

Housing

Weight:
174

mechanical data

depth:
121

Acorda o nota:

Produse asemanatoate