Caracteristici
Ambient temperature, maximum:
55
Automatic reset function:
Yes
Basic quantity unit:
Piece
Cable section, maximum:
2.5 mm²
Cable section, minimum:
0.25 mm²
Climatic stress:
EN 60068-2-3; BG-GS-ET-14
Conduction resistance, maximum:
40
Contact resistance, maximum:
0.1
Control category to EN13849:
3
Current, Utilisation category AC-15:
3
Current, Utilisation category DC12:
0.1
Current, Utilisation category DC13:
2
Degree of pollution to IEC/EN 60664-1:
2
Drop-out delay in case of emergency, typically:
20
Drop-out delay in case of power failure, typically:
80
EAN ( European Article Number):
4030661338507
EAN (European Article Number):
4030661338507
eCl@ss number, Version 9.0:
27-37-18-19
Electrical power consumption:
5
EMC rating:
EMC-Directive
Enclosure material:
Glass-fibre, reinforced thermoplastic
Faults:
Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module; Failure of or functional fault on the safety relay
Input resistance at GND:
4000
Input signal, HIGH Signal "1":
10 … 30 VDC
Input signal, LOW Signal "0":
0 … 2 VDC
Integral System Diagnostics, status :
Yes
Material of the contacts, electrical:
Ag-Ni 10 and 0.2 µm gold-plated
Mechanical life, minimum:
20000000
Mounting:
Snaps onto standard DIN rail to EN 60715
Note (applications):
Safety sensor; Guard system
Note (Contact resistance):
in new state
Note (Delivery capacity):
Phased-out product
Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults):
The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; To secure a guard door up to PL d and Category 3; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; Modification for 2 NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals X3 and X4. In this configuration, the short-circuit detection becomes inoperative.; Inversion of the output function: By establishing a bridge between X5 and X6, the output function of the additional outputs can be altered. This control can also be realised when e.g. a PLC is running (24 VDC at terminal X6).; Expansion of the enable delay time. The enable delay time can be increased from X7 s to X8 s by mounting a jumper connection between the terminals 0,1 and 1.; Monitoring a guard door using 2 position switches with safety function.; The NC contact A must have positive break when the guard door is opened.; Category 3 to ISO 13849-1 can also be achieved using only one safety switch with one NO and one NC contact. Exclusion of faults due to breakage or loosening of the actuating element or the actuating head as well as releasing, dismantling.; The feedback circuit monitors the position of the positive-guided NC contacts of the contactors K3 and K4.; If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and X2.
Notice:
for max. 50,000 switching cycles/year and max. 80% contact load
Number of safety contacts:
3
Number of signalling outputs:
2
Number of undelayed semi-conductor outputs with signaling functi:
2
Overvoltage category:
III
Performance level, up to:
d
Product type description:
AES 2335
Protection class of Clips or Terminals:
IP20
Protection class of the Clearance:
IP54
Protection class of the enclosure:
IP40
Pull-in delay at automatic start, maximum, typically:
100
Pull-in delay at RESET, typically:
20
Rated AC voltage for controls at DC minimum:
20.4
Rated AC voltage for controls, 50 Hz, minimum:
20.4
Rated AC voltage for controls, 60 Hz, minimum:
20.4
Rated control voltage at AC 50 Hz, maximum:
253
Rated control voltage at AC 60 Hz, maximum:
253
Rated control voltage at DC, maximum:
253
Rated impulse withstand voltage:
4
Rated operating voltage:
24 ... 230 VAC/DC
Reset after disconnection of supply voltage :
Yes
Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock:
30 g / 11 ms
Safety Integrity Level (SIL), applicable for:
2
Short-circuit recognition:
Yes
Standards:
IEC 61508; ISO 13849-1
Storage and transport temperature, maximum:
70
Storage and transport temperature, minimum:
-25
Switching capacity, maximum:
250
Switching capacity, minimum:
10
Terminal Connector:
Screw connection; rigid or flexible
Terminal designations:
IEC/EN 60947-1
Tightening torque of Clips:
0.6
Voltage, Utilisation category AC15:
230
Voltage, Utilisation category DC12:
24
Voltage, Utilisation category DC13:
24
Wire breakage detection :
Yes
Housing
mechanical data