• Nu esti logat

    Intra in cont

SRB211ST/CC (V.2)


Stop category 1


Producător: Schmersal Cod produs: 101210352 Disponibilitate: Solicita stoc Cantitate disponibila: 0 buc.
Solicita produs
  • 2 safety contacts, STOP 0; 1 safety contact, STOP 1
  • 1 Signalling output
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

Caracteristici

Ambient temperature, maximum:
60

Ambient temperature, minimum:
-25

Automatic reset function:
Yes

Basic quantity unit:
Piece

Cable section, maximum:
1.5 mm²

Cable section, minimum:
0.25 mm²

Category, Stop 0:
4

Category, Stop 1:
3

Certificates:
CCC; cULus; EAC; TILVA

Climatic stress:
EN 60068-2-78

Common Cause Failure (CCF), minimum:
65

Conduction resistance, maximum:
40

Contact resistance, maximum:
0.1

Current, Utilisation category DC12:
0.1

Current, Utilisation category, AC15:
3

Current, Utilisation category, DC13:
2

Degree of pollution to VDE 0110:
2

Diagnostic Coverage (DC) Level, Stop 0:
≥ 99

Diagnostic Coverage (DC) Level, Stop 1:
> 60

Drop-out delay in case of emergency, typically:
30

Drop-out delay in case of power failure, typically:
80

EAN ( European Article Number):
4030661444703

EAN (European Article Number):
4030661444703

Earth connection detection:
Yes

eCl@ss number, Version 9.0:
27-37-18-19

Electrical power consumption:
2.4

Electronic Fuse:
Yes

EMC rating:
EMC-Directive

Enclosure material:
Glass-fibre reinforced thermoplastic, ventilated

Feedback circuit :
Yes

Frequency range:
50; 60

Gross weight:
250.000

Height:
100

Indicated operating states:
Position relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>; Position relay K3/K4

Integral System Diagnostics, status :
Yes

Material of the contacts, electrical:
AgSn0, Ag-Ni, self-cleaning, positive drive

Mechanical life, minimum:
10000000

Mission Time:
20

Mounting:
Snaps onto standard DIN rail to EN 60715

Net weight:
250.000

Note (applications):
Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light curtain

Note (Contact resistance):
in new state

Note (General):
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Note (Wiring diagram):
The wiring diagram is shown with guard doors closed and in de-energised condition.; Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge.; Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2).; The control recognises cross-short, cable break and earth leakages in the monitoring circuit.; For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 ; Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential.; The safety enabling circuit 37/38 conforms to EN 60204-1 for STOP Category 1. The safety enabling circuits 13/14 and 23/24 conform to EN 60204-1 for STOP Category 0.; F1 = Hybrid fuse

Number of LEDs:
6

Number of openers:
2

Number of safety contacts:
3

Number of Safety contacts, STOP 0:
3

Number of Safety contacts, STOP 1:
2

Number of signalling outputs:
1

Overvoltage category:
III

Performance level, stop 0, up to:
e

Performance level, stop 1, up to:
d

PFD value:
0.000053

PFH-Value Stop 0:
0.00000002

PFH-Value Stop 1:
0.0000002

Product group:
Initial

Product name:
SRB 211ST

Product type description:
SRB211ST/CC (V.2)

Protection class of Clips or Terminals:
IP20

Protection class of the Clearance:
IP54

Protection class of the enclosure:
IP40

Pull-in delay at automatic start, maximum, typically:
250

Pull-in delay at RESET, typically:
20

Rated AC voltage for controls at DC minimum:
20.4

Rated AC voltage for controls, 50 Hz, minimum:
20.4

Rated AC voltage for controls, 60 Hz, minimum:
20.4

Rated control voltage at AC 50 Hz, maximum:
26.4

Rated control voltage at AC 60 Hz, maximum:
26.4

Rated control voltage at DC, maximum:
28.8

Rated impulse withstand voltage:
4

Rated operating voltage:
24 VAC -15% / +10%; 24 VDC -15% / +20%, residual ripple max. 10 %

Removable Terminals:
Yes

Replacement article number:
101211929

Reset edge detection:
Yes

Resistance to vibrations to EN 60068-2-6:
10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock:
30 g / 11 ms

Safety Integrity Level (SIL), Stop 0, applicable for:
3

Safety Integrity Level (SIL), Stop 1, applicable for:
2

Short-circuit recognition:
Yes

Standards:
IEC 61508; EN 60947-5-1

Start input:
Yes

Stop-Category:
0; 1

Storage and transport temperature, maximum:
85

Storage and transport temperature, minimum:
-40

Switching capacity, maximum:
24

Switching capacity, minimum:
10

Terminal Connector:
Spring pulley connection; rigid or flexible

Terminal designations:
IEC/EN 60947-1

Tightening torque of Clips:
0.6

Voltage, Utilisation category DC12:
24

Voltage, Utilisation category, AC15:
230

Voltage, Utilisation category, DC13:
24

Width:
22.5

Wire breakage detection :
Yes

Housing

Weight:
280

mechanical data

depth:
121

Acorda o nota:

Produse asemanatoate


Parteneri